APC Easy UPS SRV RM 6000VA 230V ,with RailKit, External Battery Pack (SRV6KRIRK)
APC Easy UPS SRV RM 6000VA 230V (SRV6KRIRK) is a high-capacity, rack-mountable online UPS designed to give your critical IT infrastructure the power protection it deserves. With 6 kVA / 6 kW capacity, pure sine wave double-conversion technology, and extended runtime via external battery pack, it ensures uninterrupted, stable power delivery to servers, network equipment, storage arrays, and mission-critical systems — even under unstable mains conditions. Its built-in rail kit makes rack installation simple, while LCD monitoring, SmartSlot network card support, and robust surge, overload, and EMI/RFI protections deliver enterprise-grade reliability. Ideal for data centers, server rooms, telecommunications closets, medical IT, and any environment where power continuity is non-negotiable.
Description
Technical Specifications
Power & Output
-
Rated Capacity: 6.0 kVA / 6.0 kW
-
Topology: Double-conversion Online UPS (true online)
-
Output Voltage (nominal): 230 V AC
-
Selectable Output Voltages: 220 V / 230 V / 240 V
-
Output Frequency: 50/60 Hz ±3 Hz (synchronized to mains)
-
Waveform Type: Pure sine wave
-
Load Crest Factor: 3:1
-
Bypass: Internal bypass (automatic and manual) for fault tolerance & maintenance bypass support
Input
-
Input Voltage (Nominal): 230 V AC (supports 220 / 230 / 240 V)
-
Input Voltage Range: ~110 – 300 V (at half load), ~176 – 300 V (at full load) depending on configuration.
-
Input Frequency Range: 40 – 70 Hz (auto-sensing)
-
Input Connection: Hard-wired 3-wire (1P + N + E) for both input and output.
-
Power Factor (Input): 0.99 (or close to unity), helping compatibility with generator / mains supply design.
Battery & Runtime
-
Battery Type: Sealed lead-acid (VRLA), maintenance-free.
-
Battery Bank Voltage: 192 V (external / extended runtime battery pack)
-
Battery Recharge Time: Approx. 3–4 hours (to full charge) depending on battery pack configuration.
-
Runtime (Example): > 7 minutes at 70% load (with external battery pack), variable depending on load and battery configuration.
-
Battery Management: Intelligent battery management and charger for optimized battery life and reliability.
Management & Communications
-
User Interface: Multifunction LCD status & control console for real-time monitoring and UPS configuration.
-
Communication Ports:
-
RS-232 (DB-9)
-
USB port
-
SmartSlot / Intelligent Slot for optional network management card (e.g. network-based monitoring, remote shutdown)
-
Audible Alarms: Battery mode alarm, low battery warning, continuous tone overload warning. Emergency Power Off (EPO): Supported
-
-
Communication & Management Software Support: Compatible with central UPS management platforms (e.g. EcoStruxure IT or third-party monitoring software) when network card is installed. Form Factor: Rack-mount (4U or 5U depending on configuration) — suitable for 19″ server racks.
-
Dimensions (UPS unit): approx. Height 173 mm × Width 438 mm × Depth 710 mm (for the SRV6KRILRK version with external battery pack / rail kit)
-
Weight (Net): ~61 kg (unit only)
-
Color: Black (standard rack server look)
Protection & Safety
-
Surge Energy Rating: 600 Joules (surge / transient protection)
-
Overload Protection / Short-Circuit Protection: Yes, with automatic bypass fallback for uninterrupted power.
-
EMI / RFI Filtering: Included to ensure clean power output.
-
Approvals & Certifications: CE, IEC 62040-1, IEC 62040-2 (and other regional safety/ EMC standards as applicable)
-
Protection Class: IP20 (standard rack environment protection)
Environment & Operating Conditions
-
Operating Temperature Range: 0 °C – 40 °C
-
Operating Humidity: 0–95% (non-condensing)
-
Operating Altitude: Up to 3,000 meters above sea level
-
Storage Temperature: –15 °C – 60 °C
-
Noise Level (approx.): 55 dBA at 1 meter distance
Warranty
-
Standard Warranty: 2 years (unit + battery)